STC measures the sound that travels through the air, like voices and TVs. IIC measures the sound that comes from impact, like footsteps and dropped keys. Hard flooring buyers usually need to worry about the second one.
Why Noise Ratings Matter More Than Most Buyers Think
Most people shop for flooring by looks, price and wear layer. Very few ask how loud the floor will be. The noise problem shows up later, after the floor is down and the neighbor below starts calling.
Two ratings control how quiet a floor feels:
- STC (Sound Transmission Class) — sound that travels through the air.
- IIC (Impact Insulation Class) — sound made by things hitting the floor.
The names look similar. The tests are not. A floor can pass one and still fail the other.
This matters most if you are:
- Buying for a condo, apartment or townhouse.
- Putting hard flooring on a second story.
- Replacing carpet with vinyl, laminate or tile.
- Working under HOA or building rules.
- Adding a home office, gym or playroom above a living space.
Ratings are not marketing numbers. They are lab test results, the same way a DCOF rating tells you how slip-resistant a tile is. Read them right, and you avoid an expensive mistake.
STC Explained: The Rating for Airborne Sound
STC stands for Sound Transmission Class. It measures how well a wall, ceiling or floor blocks sound that travels through the air.
Airborne sound is the noise you hear through a barrier:
- Voices and phone calls.
- TV and music.
- Barking dogs.
- Appliance hum.
The test runs in a lab. Speakers play sound on one side of the assembly. Microphones measure what comes through. The result is one number. Higher is better.
Rough guide to the numbers:
- 25 to 30: you can hear a conversation and follow it.
- 35 to 40: speech is audible but hard to make out.
- 45 to 50: loud speech drops to a faint murmur.
- 55 and up: most normal household noise stops being an issue.
Here is the part that surprises buyers. Your floor covering does almost nothing for STC. Industry guidance is blunt about it: carpet, vinyl, wood, tile and stone add no real improvement to STC, because that number comes mostly from the mass of the structure (TCNA guidance via Why Tile).
STC also misses bass and low rumble.
IIC Explained: The Rating That Decides How Loud Your Floor Feels
IIC stands for Impact Insulation Class. It measures sound created when something strikes the floor. That sound passes down into the room below.
Impact sound is the noise your neighbor complains about:
- Footsteps, especially heels.
- Dropped keys, toys and phones.
- Chair and table legs scraping.
- Pet claws.
- Kids running.
A standard tapping machine runs on the floor. Microphones in the room below record the result. Higher is better.
What the numbers mean in practice:
- IIC 50: the lab minimum written into building code.
- IIC 55 to 60: what acoustic professionals usually target, because finished buildings test lower than labs.
- IIC 60 and up: the goal in higher-end condo buildings.
Two facts explain most noise complaints about hard flooring.
First, the bare structure starts low. A 6-inch concrete slab sits near IIC 28. Wood-frame floors are not much better.
Second, hard surfaces make it worse. A hard finish can drop IIC by 10 to 25 points when no underlayment is used. That is the real cost of swapping carpet for vinyl plank or tile.
One more rule to remember: IIC belongs to the whole floor assembly, not to the plank.
IIC vs STC: The Side-by-Side Comparison
|
|
STC |
IIC |
|
What it measures |
Sound through the air |
Sound from impact on the floor |
|
Everyday example |
Neighbor's TV |
Neighbor's footsteps |
|
Where it applies |
Walls, ceilings and floors |
Floor-ceiling assemblies only |
|
Lab test standard |
ASTM E90 |
ASTM E492 |
|
Field test standard |
ASTM E336 |
ASTM E1007 |
|
Code minimum (IBC §1206) |
50 lab / 45 field |
50 lab / 45 field |
|
Does your flooring choice change it? |
Barely |
Yes, a great deal |
|
What actually improves it |
Mass, insulation, sealed gaps |
Underlayment and isolation layers |
Act on the last two rows. If voices are the problem, the floor is the wrong place to spend money. If footsteps are, it is exactly the right place.
What Ratings Do You Actually Need?
That depends on where you live and who has to approve the job.
Building code. The International Building Code sets the floor for multi-family housing in Section 1206:
- STC 50 and IIC 50 when tested in a lab.
- 45 for either when tested in the finished building.
- Applies to assemblies that separate one unit from another, or a unit from a hallway, stairwell or laundry room.
- Does not apply to walls inside your own unit.
Those numbers have stayed the same across the 2018, 2021 and 2024 editions. Still confirm which edition your city has adopted.
HOA and condo rules. These are often stricter than code. Many boards want IIC 55 or higher before approving hard flooring over an occupied unit, plus the test report. Some require field testing after installation.
Single-family homes. No rating is required. The numbers still help if you are putting hard flooring above a bedroom, a home office or a rental unit.
Before you order anything, get the requirement in writing. Ask three questions:
- What IIC number do we need to hit?
- Is that a lab number or a field number?
- Does the rating need to cover the full assembly or just the underlayment?
How Each Flooring Type Behaves
No floor has a fixed IIC score. But each material starts from a different place.
|
Flooring type |
Impact noise on its own |
What it usually needs |
|
Quietest option; often IIC 55+ applied directly |
Little or nothing |
|
|
Soft and naturally absorbent |
Standard pad in most cases |
|
|
Thin, dense and hard; bare vinyl often tests under IIC 45 |
Acoustic underlayment, even with an attached pad |
|
|
Floating planks can sound hollow and sharp |
A dense acoustic mat |
|
|
Quieter than solid wood, but still hard |
Acoustic mat for floating installs |
|
|
Nails tie it to the joists and pass impact down |
Sound mat or a treated ceiling below |
|
|
Hardest surface and bonded to the slab |
Uncoupling or isolation membrane |
Use this as a starting point, not a spec. The same plank can test 15 points apart on two different buildings.
Underlayment: The Biggest Lever You Control
You cannot change the concrete under your unit. You can change what sits between that concrete and your new floor.
This is where a third rating appears on spec sheets: Delta IIC, written as ΔIIC. It measures how many points an underlayment adds to a bare reference slab. Use it to compare one mat against another.
Two rules keep you out of trouble:
- Under hard flooring, look for a ΔIIC around 22 or higher.
- ΔIIC does not transfer between buildings, and two products' values never add together.
Do the math before you buy. A 6-inch slab near IIC 28, plus a mat worth ΔIIC 16, lands around IIC 44. That is a real improvement and still short of code.
How the materials compare:
- Rubber: highest performance; 5 mm to 8 mm rolls are common for condo projects.
- Cork: strong acoustic performance and naturally resistant to mold.
- Fiber and felt: good value under laminate and engineered wood.
- Standard foam: mostly comfort and moisture control, not sound control.
One warning. The thin pad attached to a click-lock plank is not an acoustic underlayment. It is there for comfort and small subfloor flaws.
When you read a test report, check four things:
- Was the test run on concrete or on wood framing?
- Which finish floor was installed on top?
- Is the number IIC or ΔIIC?
- Did the tested assembly include a ceiling below?
An "IIC 60" earned over a thick slab with a drywall ceiling will not repeat on a wood-frame second story.
Your Pre-Order Noise Checklist
Run through these steps before you place the order.
-
1 Get the requirement in writing. Ask your HOA, builder or city for the IIC target and whether it is lab or field tested.
2 Identify your structure. Concrete slab or wood joists? Is there a finished ceiling below? Both change the result more than the plank does.
3 Name the real problem. Footsteps point to IIC. Voices and TV point to STC, which means walls and ceilings, not flooring.
4 Choose the finish floor first, then match the mat. Harder surface, stronger underlayment.
5 Ask for the full assembly test report. A number for the mat alone proves very little.
6 Check your heights. A 5 mm to 8 mm acoustic mat affects door clearance, transitions and appliance fit.
7 Watch the edges. Leave the expansion gap, keep planks off the baseboard, and seal penetrations. Sound leaks through contact points.
8 Plan soft touches. Area rugs, felt pads and the right surface under rolling chairs cut noise cheaply.
9 Keep the paperwork. Board approvals and test reports protect you later, including at resale.
Frequently Asked Questions
Q) Is IIC or STC more important when buying flooring?
A) IIC. Your flooring choice changes impact sound a lot and airborne sound almost not at all.
Q) What is a good IIC rating for a condo?
A) IIC 50 meets most codes. Aim for 55 to 60 if the unit below is occupied, since finished buildings test lower than labs.
Q) Does thicker flooring mean a quieter floor?
A) No. Density and resilience matter more than thickness. A thin rubber mat can beat a thick foam pad.
Q) Will an acoustic underlayment alone get me to IIC 50?
A) Sometimes. Over a thin wood-frame floor with no ceiling treatment, often not. The whole assembly decides.
Q) Do I need acoustic underlayment under vinyl plank?
A) In a condo or on a second story, almost always. Bare vinyl over a slab is one of the loudest combinations for the room below.
Q) Is carpet still the quietest choice?
A) Yes, which is why many buildings restrict only hard surfaces.
Q) Can I test my floor after installation?
A) Yes. A field test measures AIIC in the finished space. Many HOAs accept it as proof of compliance.


